New - TITAN-RC Probe with reduced contact tip width

MPI Corporation expands the family of the RF TITAN Probe by introducing the TITAN-RC Probe. The new probe model features the contact tip width reduced by 33 % down to 20 μm. Fully aligned with the industry trend towards further reduction of the pad size for RF devices and ICs, the TITAN-RC probe significantly reduces cost of test for next generation commercial RF and mm-wave silicon devices and ICs. It enables accurate, and reproducible measurement results obtained for Si devices with Al pad metallisation as small as 30 x 35 μm. TITAN-RC probes are available in GSG tips configuration with probe pitch from 50 μm to 150 μm.

Trennlinie

TITAN-RC Probes in contact (left) and the probes footprint on the Al pads of the device (right), respectively.

Trennlinie

Mechanical Characteristics

 Cantilever needle material: Ni alloy

  • Body material: Al alloy
  • Contact pressure @2 mils overtravel: 20 g
  • Lifetime, touchdowns: > 1,000,000
  • Ground and signal alignment error[1]: ± 3 μm[1]
  • Planarity error[1]: ± 3 μm[1]
  • Contact footprint width: < 20 μm
  • Contact resistance on Au: < 3 mΩ
  • Thermal range: -60 °C to 175 °C

 

[1] Parameter may vary depending upon tip configuration and pitch.

Trennlinie
Trennlinie
Online Information

Find a suitable product for your needs.

Application Support

Ask us for a tailored solution for your metrology application.

Call ATV

You are looking for a solution or need help? Call us for professional advise:

+49 351 2138640

Please contact us
Address: Heilbronner Str. 17, 01189 Dresden, Germany
Phone: +49 (0) 351 2138640
Fax: +49 (0) 351 2138650
E-Mail: atv@atv-systems.de
© 2019 AutomatisierungsTechnik Voigt GmbH
First Contact in Measurement Technology

Our website uses cookies to monitor how the site is used. If you continue to browse we will assume your permission to use cookies.